LAR Process Analysers

LAR Process Analysers

LAR process analysers from Process Insights measure the key water quality parameters for wastewater and process water online and in the laboratory. The range covers the QuickTOCultra for total organic carbon, the QuickCODultra and QuickCODlab for chemical oxygen demand by thermal oxidation without toxic reagents, the BioMonitor for short-time BOD and sludge activity, and the NitriTox for toxicity early warning using nitrifying bacteria. Territory Instruments lists LAR analysers as quote items. Request a quote with your sample and application details.

Products

← Back to Process Insights

​
​
Sort by: Featured
​

5 results

Filters

Product families

All Process Insights
LAR Process Analysers
COSA Xentaur Calorimeters
Extrel Mass Spec Gas Analyzers
Tiger Optics Laser Gas Analyzers

Availability

1 option available

Category

1 option available

Product Type

LAR BioMonitor Online BOD Analyzer

LAR BioMonitor Online BOD Analyzer

LAR Process Analysers · BioMonitor

The LAR BioMonitor is an online analyzer for continuous biochemical oxygen demand (BOD) measurement in wastewater and industrial process water. It measures respiration of an active biomass in a two-stream system, giving a short-time BOD result in minutes rather than the five days of a laboratory BOD test, along with sludge activity (ASR) data for process control. Key features: - Continuous two-stream respiration measurement for short-time BOD - Measures total BOD and activated sludge respiration (ASR) - Response from 3 to 4 minutes - Accuracy and repeatability of 2% of full scale - 10.4" touchscreen with USB and TCP/IP remote access - IP54 cabinet for installation close to the process Typical applications: Municipal wastewater treatment plant inflow and effluent, Industrial wastewater and effluent monitoring, Process water, pure water and wastewater in chemical manufacturing, Load-based control of biological treatment stages. Specifications: - Measurement: BOD 1–50 mg/l up to 1–200,000 mg/l; ASR 0–5 mg/l/min - Accuracy and repeatability: 2% FSR - Response time: min. 3–4 minutes - Sample temperature: 5–25°C - Outputs: 0/4–20 mA, RS232, USB, TCP/IP remote access - Power: 230 V or 115 V - Enclosure: IP54; approx. 630 × 862 × 575 mm, approx. 90 kg It is part of the LAR Process Analysers range, supplied across Australia by Territory Instruments. Share your application details and our team will help you choose the right BioMonitor configuration.

Price on requestFor quote

Configure
LAR NitriTox Online Toxicity Analyzer

LAR NitriTox Online Toxicity Analyzer

LAR Process Analysers · NitriTox

The LAR NitriTox is an online toxicity analyzer that warns wastewater operators when toxic substances arrive at a treatment plant. It measures the oxygen consumption of nitrifying bacteria, which are highly sensitive to toxins, so a drop in their activity signals a toxic load before it damages the biological treatment stage. Key features: - Toxicity measurement using nitrifying bacteria, based on DIN EN ISO 9509 - Range of 0–100% toxicity - Measuring cycle of 12–15 minutes with a 5 minute response - Early warning to protect the biological treatment stage - Steel IP54 cabinet for online installation - Analogue 0/4–20 mA and RS232 outputs Typical applications: Wastewater treatment plant inflow protection, Industrial effluent from chemical, pulp and paper and food processing, Toxicity monitoring before discharge to the environment, Surface water monitoring. Specifications: - Principle: oxygen consumption of nitrifying bacteria (DIN EN ISO 9509:2006) - Range: 0–100% toxicity - Measuring cycle: 12–15 minutes; response time 5 minutes - Outputs: 0/4–20 mA, RS232 - Power: 230 V or 115 V - Enclosure: IP54 steel; approx. 630 × 1265 × 580 mm, approx. 70 kg It is part of the LAR Process Analysers range, supplied across Australia by Territory Instruments. Share your application details and our team will help you choose the right NitriTox configuration.

Price on requestFor quote

Configure
LAR QuickCODlab Laboratory COD Analyzer

LAR QuickCODlab Laboratory COD Analyzer

LAR Process Analysers · QuickCODlab

The LAR QuickCODlab is a laboratory analyzer that determines chemical oxygen demand (COD) by thermal combustion, without the toxic reagents used in the dichromate method. Results are available in about three minutes, and samples can be injected with the eSyringe or loaded from an AutoSampler. Key features: - Thermal combustion COD without dichromate or mercury reagents - Result in about 3 minutes - Five measuring ranges from 1–100 mg/l up to 2,000–10,000 mg/l - eSyringe injection or AutoSampler operation - Windows software with USB/LAN connection and CSV export - Compact IP54 benchtop housing Typical applications: Industrial effluent monitoring in industrial wastewater, Influent load monitoring in municipal wastewater treatment facilities, Laboratory COD checks for process and discharge water. Specifications: - Principle: thermal combustion - Ranges: 1–100, 10–200, 100–1,000, 1,000–3,000 and 2,000–10,000 mg/l - Response time: approx. 3 minutes - Sample introduction: eSyringe or AutoSampler - Carrier gas: nitrogen - Interface: Windows software, USB/LAN, CSV export - Enclosure: IP54; approx. 500 × 450 × 450 mm, approx. 37 kg It is part of the LAR Process Analysers range, supplied across Australia by Territory Instruments. Share your application details and our team will help you choose the right QuickCODlab configuration.

Price on requestFor quote

Configure
LAR QuickCODultra Online COD Analyzer

LAR QuickCODultra Online COD Analyzer

LAR Process Analysers · QuickCODultra

The LAR QuickCODultra is an online analyzer for chemical oxygen demand (COD) and total oxygen demand (TOD) in difficult industrial wastewater. It oxidises the complete sample at 1,200°C without a catalyst, following ASTM D6238, so salty, fatty and particle-laden samples can be measured in one to two minutes without reagents. Key features: - Thermal oxidation at 1,200°C with no catalyst or reagents - COD/TOD measurement to ASTM D6238 - Results in 1–2 minutes - Handles particles up to 800 µm - Ranges up to 250,000 ppm, with dilution up to 1,000,000 ppm - Optional ATEX/UKEX version for Zone 1 or Zone 2 Typical applications: Industrial wastewater from chemical and petrochemical plants, Municipal wastewater treatment plant inflow, Food and beverage process water, Monitoring of high-load and difficult sample matrices. Specifications: - Principle: thermal oxidation at 1,200°C, non-catalytic (ASTM D6238, TOD) - Ranges: 150–30,000 ppm or 20,000–250,000 ppm; dilution up to 1,000,000 ppm - Accuracy and repeatability: max. 2% FSR - Response time: 1–2 minutes - Particle size: up to 800 µm; sample temperature 5–60°C - Outputs: 0/4–20 mA, RS232 - Enclosure: IP54, optional ATEX/UKEX Zone 1/2; approx. 848 × 1100 × 635 mm, from 115 kg It is part of the LAR Process Analysers range, supplied across Australia by Territory Instruments. Share your application details and our team will help you choose the right QuickCODultra configuration.

Price on requestFor quote

Configure
LAR QuickTOCultra Online TOC Analyzer

LAR QuickTOCultra Online TOC Analyzer

LAR Process Analysers · QuickTOCultra

The LAR QuickTOCultra is an online total organic carbon (TOC) analyzer built for the roughest wastewater applications. Thermal oxidation at 1,200°C handles sticky, fatty, salty and high-particle samples, and the analyzer can also report TC, TIC and optional COD and TNb from the same platform. Key features: - Thermal oxidation at 1,200°C for complete sample oxidation - TOC, TC and TIC, with optional COD and TNb - Range from 0.1 mg/l to 50,000 mg/l TOC, with dilution up to 500,000 mg/l - Handles salt concentrations up to 30% NaCl - Response time of about 3 minutes - IP54 standard, with IP65 and EXp Zone 1/2 versions Typical applications: Water and wastewater treatment plants, Chemical and pharmaceutical manufacturing, Food and beverage production, Environmental monitoring of rivers and lakes, Ultrapure water monitoring in semiconductor manufacturing. Specifications: - Principle: thermal oxidation at 1,200°C (DIN EN 1484, ISO 8245, EPA 415.1, ASTM D-5173) - Range: 0.1–50,000 mg/l TOC; dilution up to 500,000 mg/l - Parameters: TOC, TC, TIC; optional COD and TNb - Accuracy and repeatability: 2% FSR - Response time: approx. 3 minutes - Communication: LAN/WLAN - Enclosure: IP54, optional IP65 or EXp Zone 1/2; approx. 848 × 1100 × 635 mm, from 115 kg It is part of the LAR Process Analysers range, supplied across Australia by Territory Instruments. Share your application details and our team will help you choose the right QuickTOCultra configuration.

Price on requestFor quote

Configure