Every pneumatic process valve needs a pilot valve to switch its air and, usually, feedback to confirm its position. You can do that centrally with a valve island in the control cabinet, or at the valve with a control head. The right architecture depends on valve count, distance, hygiene and hazardous-area requirements.
This guide explains both approaches using Bürkert's AirLINE valve islands, pilot valves and control heads, from the Type 8652 to the Type 8681.
Centralised: valve islands in the cabinet
A valve island groups many pilot valves on one manifold with a single fieldbus connection, and air lines run out to each valve. It is efficient when valves are clustered and the cabinet is close.
- The Bürkert Type 8652 AirLINE is developed for process automation. Bürkert lists diagnostics on an LC display in clear text and symbols, safety-related shut-off of valves, PROFINET S2 system redundancy, check valves in the exhaust ducts against unplanned actuation, and Ex variants for ATEX/IECEx Zone 2 and Class I, II, III Div 2.
- The Type 8644 AirLINE combines fieldbus modules, pilot valves and I/O on a standard rail, with direct connection to the WAGO I/O System 750.
- For Zone 1/21, the Type 8650 AirLINE Ex uses intrinsically safe electronics and valves that can be replaced during operation, controlled via PROFINET IO or PROFIBUS DP with Siemens SIMATIC ET 200iSP I/O.
In the field: IP65/67 valve islands
When there is no cabinet near the valves, the Type 8653 AirLINE Field is an IP65/67 valve island designed for installation in the field, with CANopen, IO-Link or büS interfaces and the same diagnostics and pneumatic safety functions.
Decentralised: control heads on each valve
A control head sits on top of the valve actuator and integrates the pilot valves, position sensing and communication. Air tubing to the valve disappears, and wiring is one bus cable.
- The Bürkert Type 8691 is designed for ELEMENT Type 21xx valves, with a contact-free inductive position sensor and teach function, a colour status display, integrated pilot air ducts with spring chamber aeration, and AS-Interface, IO-Link or büS. ATEX II cat. 3G/D and IECEx variants are available.
- The Type 8681 is optimised for hygienic process valves and adapts to standard butterfly, ball, single-seat and double-seat valves, with three switching points, a coloured status LED and a magnetically encoded manual override that works with the housing closed.
| Valve island (8652 / 8644) | Field valve island (8653) | Control head (8681 / 8691) | |
|---|---|---|---|
| Location | Control cabinet | Field, IP65/67 | On each valve |
| Air tubing to valves | One line per valve | Short lines from the field island | None; pilot air integrated |
| Position feedback | Separate sensors or wiring | Separate sensors | Integrated, teach function |
| Best fit | Many valves near a cabinet | Valve clusters without a cabinet | Hygienic plants, spread-out valves |
Single pilot valves for actuators
Not every valve justifies an island or a control head. For individual quarter-turn actuators and process valves, the Type 6519 pilot valve offers 3/2, 5/2 or 5/3-way functions with G 1/4, 1/4 NPT or NAMUR flange connections and Ex variants; Bürkert states that certain monostable functions can reach SIL 2 depending on the safety architecture. The compact Type 6524 uses a flipper pilot for high pressures with low power and is suited to valve island use.
Selection checklist
- Count the valves and map how far they are from the cabinet.
- Many valves near a cabinet: a valve island such as the 8652 or 8644.
- Clusters in the field: the 8653 AirLINE Field.
- Hygienic or spread-out valves: control heads, the 8681 for hygienic valves or the 8691 for ELEMENT valves.
- Hazardous areas: check Zone 2 variants of the 8652 or the 8650 for Zone 1/21, and Ex pilot valves such as the 6519.
Territory Instruments can quote Bürkert AirLINE islands, pilot valves and control heads configured for your fieldbus and valve list.
Frequently asked questions
What is the difference between a valve island and a control head?
A valve island groups many pilot valves on one manifold, usually in a cabinet, with air lines out to each valve. A control head mounts on an individual process valve and integrates its pilot valves, position feedback and communication.
Which Bürkert valve island can be mounted in the field?
The Type 8653 AirLINE Field is designed for field installation with IP65/67 protection.
Is there a Bürkert valve island for Zone 1?
Yes. The Type 8650 AirLINE Ex is designed for potentially explosive atmospheres in Zones 1/21 with intrinsically safe electronics and valves.
Which control head suits hygienic butterfly and double-seat valves?
The Bürkert Type 8681 is optimised for hygienic process valves and adapts to standard butterfly, ball, single-seat and double-seat valves.